GTU-800KVA/220KV -
Wuhan Sangao Electrical Test Installations Limit Co.
SF6 gas -filled testing transformers are especially designed for GIS in the factory and on-site test,and for testing all GIS switchgears and GIS components such as insulators,insulating tension pole,GIS voltage transformer and so on,the PD test can be performed under the general environment because of the merits of encapsulation ,the PD level of our equipment can be lee than 3pC,and it can be added a HV bushing to perform the withstand voltage test at the same time.
-
Ivium Technologies B.V.
The Peripheral Level Transformer (PLT) is an adapter module that increases the voltage of the analog inputs&outputs for easy communication with external devices. It is connected between the instrument and the periphery.
-
PMT20030 -
Power Measurement Technologies Inc.
A hand held instrument for polarity identification of current, voltage and power transformers with an operable ratio range from 1:1 to greater than 5000:1.
-
Supreme Instrument Laboratories
The two voltage vectors, one from Standard Potential Transformer and the other from the Potential Transformer under test energies the high permeability magnetic core and then associated windings try to annual the residual magnetism which occurs due to error. The differential vectors will be proportional to phase error and ratio error magnitudes.
-
HIGHVOLT Prüftechnik Dresden GmbH
Pulse Voltage Test Systems are used for surge testing on transformers, cables, gas insulated switchgear (GIS), arresters, and other high voltage equipment.
-
SBF -
Wuhan Sangao Electrical Test Installations Limit Co.
Specificationstripping test transformer1.easy to operate, with stable features.2.Can meet the induced voltage withstand request ofTtripping est transfromer,frequency tripling transformer, frequency tripling generator, frequency power generatorproduct features1.Easy to operate, with stable features.2. Can meet the induced voltage withstand request of the transformer, mutual inductor.product parameters1. Output voltage: three phases 380V 50HZ2. Input voltage: single phase 0~300V/0~500V(continuously adjustable) frequency:150HZ3. Output capacity: 5KVA and above.Harmonic distortion:<5%-8%4. No-load running time:≤5minutes5.duration of the measured equipment under rated voltage: 40 seconds
-
CBT4 -
Shanghai Powoo Industry Develop Group Limited
- Completely enclosed, good mechanical behavior, suitable for various environments, strong voltage isolation ability, delicate appearance; - more space in meter can be saved with combined current transformer in comparison to that of the same number of single form current transformers; - HLX-2 is used for 3-phase-3-wire circuits; HLX-3 is used for 3-phase-4-wire circuits;
-
DVDF -
AJIT Electronics Co.
This test setup is generally used to perform induced voltage test on the transformers. This set up consists of the USED motor and generator combination to develop the required voltage and frequency. Both generating unit and the drive motor are mounted on a common metallic frame.
-
SG3004-12(14) -
Shanghai Jiuzhi Electric Co., Ltd.
High voltage impulse test is used to assess the quality of any high voltage equipment. The test object is subjected to a fast voltage impulse of defined wave shape caused by the test object are used for detection of insulation strengths and/or faults. It is commonly used for routine testing of transformer, bushings or other high voltage equipment.
-
Phenix Technologies
Designed to generate impulse voltages that simulate lightning strokes andswitching surges as defined by IEC, ANSI/IEEE, and other national standards on:• Distribution transformers• Small power transformers• Cables (type tests)• Arrestors (impulse current tests)• Motors / generatorsTesting ApplicationsImpulse Generators andMeasurement Systems• Insulators• Bushings• GIS• Instrument transformers
-
Hilkar
Arc Furnace Reactors are serially connected reactors that are installed in the supply systems of arc furnace transformers to stabilize arc and limit the unstable arc furnace current and voltage drop which optimize their melting process. These buffer reactors are connected in series to the primary side of the furnace transformer. Typically these reactors are tapped coils and manufactured as per customer'stap requirements.
-
MR 8050 -
Schuetz Messtechnik GmbH
With the MR 8050 resistances highly inductive Resistance Meters windings of transformers, motors and reactors can be measured. (range 100 µΩ with 0.01µΩ resolution up to 6 kΩ). The performance of the test objects can be up to 800 MVA or even more. The magnetic loading of a transformer is performed quickly using a high loading voltage (60V). This is important for time critical measurements (cooling curves). The unloading of the transformers core is very fast, very safe, as the energy is total destroyed in the MR 8050.
-
Yangzhou Power Electric Co., Ltd
The test system is used to do AC voltage withstand test and PD measurement for high voltage insulation products, combined electrical equipment, instrument transformers, etc.
-
TWR-H Series -
IBEKO Power AB
Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.
-
ATG 2 -
BAUR Prüf- und Messtechnik GmbH
Cable fault location with the BAUR ATG 2. The ATG 2 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 2300 VA stray field transformer delivers a maximum voltage of 10 kV and is housed in a fully enclosed 19" housing.* Portable device for changing the fault resistance* Useful for cables that are difficult to access* Proven methods for complicated faults* Independent current and voltage control on each burning level